Skip to main content
    • About the Scottish Episcopal Church
    • Vocation & Ministry
    • Children and young people
    • Working with others
    • FAQs
    Who we are section
    • Our Church Structure
    • Bishops and their Dioceses
    • The General Synod
    • Boards & Committees
    • Code of Canons
    • Resources
    • Safeguarding
    Governance section
    • Spirituality
    • Daily Prayer
    • Liturgy
    • Celebrating the Year
    • Baptisms, Marriages & Funerals
    Worship and Prayer section

    The Daily Prayer Offices

    • Morning
    • Evening
    • Night
    • News
    • Inspires (Newsletter)
    • Vacancies
    News section

    Our online magazine

    • Sign up Now
Vacancies
Church Finder
Vacancies
Church Finder
  1. Home
  2. Resources
  3. Administration, Health & Safety, and Compliance
  4. Health & Safety Toolkit
  5. Equipment Safety Checks

Equipment Safety Checks

Administration, Health & Safety, and Compliance

  • Communicants’ Roll Declaration
  • How to make your church accessible and inclusive
  • Care of Congregational Records and Archives
  • Public Entertainment Licences
  • Copyright and Performing Rights Licences
  • Data Protection
  • Annual Statistical Return
  • Health & Safety Toolkit
    • Fire Risk Assessment
    • Equipment Safety Checks
    • Maintenance & Construction Safety
    • Food Hygiene
    • Events Safety
    • Risk Assessment
    • Reporting Injuries
    • Health & Safety Policy Statements
  1. Equipment should be inspected as part of your overall health and safety risk assessment. Such equipment ranges from hand-held power tools, ladders, hammers, drills, knives and screwdrivers to office equipment such as computers and photocopiers.
  2. You must ensure that:
    • those using equipment have enough knowledge and training to use it safely.
    • the equipment is suitable for the job including, where appropriate, the provision of safety guards and personal protective equipment
    • it is maintained to keep it safe at all times
    • it is inspected at suitable intervals if wear and tear might cause risks
  3. Certain systems in your buildings, such as the electrical system, require periodic checks to ensure that they remain functional.

Further information can be found in the HSE Guidance note: “Inspection of work equipment”.

1) Fire Extinguishers

Fire extinguishers require an annual inspection from a competent person to British Standard 5306 Part 3. Fire extinguisher servicing is a legal requirement.

In addition to the annual testing, extinguishers should be discharge tested every 5 years for water, foam and powder and 10 years for CO2. The test makes sure they actually work and are in good condition internally and must be carried out by a competent person

2) Fire Alarm

The fire alarm system should be adequately maintained. This should be done annually by the Fire Protection Company used to service the fire extinguishers.

The fire alarm system bell / klaxon should be tested weekly and the results recorded

A full evacuation exercise should be carried out annually.

3) Carbon Monoxide Detectors

Carbon monoxide detectors in areas like kitchens and boiler rooms where combustion takes place, should be tested monthly. This does not require to be done by a competent person, Detectors should be replaced every 7-10 years

4) Emergency Lighting

Emergency lighting should be tested periodically (approx. every 3 months) to ensure that all lights operate when the supply is isolated. There should be an annual discharge test for 3 hours to ensure that the lights remain functioning for at least 3 hours. The results of this test should be recorded.

5) Emergency and Fire Doors

Emergency doors should be checked monthly to ensure that they open freely and are unobstructed. Records should be maintained. Fire doors should be checked periodically to ensure that the closing mechanism operates and closes fully.

6) Portable appliance testing (PAT Tests)

All socket fed equipment should be inspected and tested every 2 years. A register of PAT tests should be maintained, and it is usual practice to ensure that the tested equipment carries a label to indicate the status & next test date.

7) Electrical (System) Inspection

Required under the IEEE Regs. The maximum period between inspections of the total system by a competent & registered electrician, is 5 years. It is recommended that this be carried out just before the SEC Quinquennial Inspection.

8) Lightning Conductors

By law, lightning protection testing must be carried out at the installation stage and then at 11-month intervals. Records must be kept.

9) Defibrillator

Where defibrillator are installed, they should be checked for battery status monthly. If necessary, this could be arranged at no cost by the First Responders. If no defibrillator exists, a notice should be displayed to indicate the location of the nearest one.

10) First Aid Kits

The first aid kits need to carry a clear sign and the contents listed and maintained on a monthly basis

General advice on safety checks in Community Halls
A useful checklist from the HSE is provided here

Please note that checks 1,2 (excluding bell tests) and 7 require to be carried out by competent contractors.

View All Resources

Accessibility Tools

Display Modes

Text Controls

Visual Aids

User Guide Accessibility Statement
General Synod of the Scottish Episcopal Church
Ground Floor West
40 Torphichen Street
Edinburgh
EH3 8JB
Scotland
  • Twitter
  • Facebook
  • YouTube
  • Vimeo
Contact Us
  • Terms & Conditions
  • Privacy Policy
  • Accessibility Statement
  • Photo / Image Credits

© 2026 General Synod of The Scottish Episcopal Church | Scottish Charity Number SC015962

Website by Hillside

Subscribe to the online newsletter of the Scottish Episcopal Church
Manage Consent

We use cookies on this website. By clicking “Accept”, you consent to the use of these cookies.

Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
Preferences
  • {title}
  • {title}
  • {title}